Remote Operation
SAS:SANDIA:TMP -100
Query Syntax: SAS:SANDIA:TMP?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:TMP?
Return Example: -1.000000e+02
16. SAS:SANDIA:PMPp
Description: Sets the PMPp in SANDIA Mode.
Syntax: SAS:SANDIA:VMPp <NRf+>
Example: Changes the PMPp to 1500.0 W.
SAS:SANDIA:PMPp 1500
Query Syntax: SAS:SANDIA:PMPp?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:PMPp?
Return Example: 1.500000e+03
17. SAS:SANDIA:VMPp
Description: Sets the VMPp in SANDIA Mode.
Syntax: SAS:SANDIA:VMPp <NRf+>
Example: Changes the VMPp to 500.0 V.
SAS:SANDIA:VMPp 500
Query Syntax: SAS:SANDIA:VMPp?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:VMPp?
Return Example: 5.000000e+02
5.6.2.9 OUTPUT Subsystem
1. OUTPut [: STATus]
Description: Enables or disables the DC Power Supply output. To stop the output,
set the output voltage to 0 volts.
Query Syntax: OUTPut [: STATus]?
Parameter: OFF | ON
Return Parameter: OFF | ON
2. OUTPut : MODE
Description: Sets the output mode. The default operating mode is “CVCC”.
Query Syntax: OUTPut : MODE?
Parameter: CVCC | TABLE |SAS
Example: OUTPut:MODE CVCC
OUTPut:MODE TABLE
OUTPut:MODE SAS
Query Syntax: OUTPut:MODE?
Query Example: OUTPut: MODE?
Return Example: CVCC or TABLE or SAS
TABLE Mode Return Example:
OUTPut:MODE TABLE
IVCurve:EDIT <NR1>
IVCurve:VT {...}
IVCurve:IT {...}
IVCurve:SELect <NR1>
OUTPut ON