Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5-48
Query Syntax: SAS:SANDIA:IRRREF?
Return Parameter: <NR1>
Query Example: SAS:SANDIA:IRRREF
Return Example: 1000
11. SAS:SANDIA:TMPREF
Description: Sets the temperature reference in SANDIA Mode.
Syntax: SAS:SANDIA:TMPREF <NRf+>
Parameter: <NRf+>
Example: SAS:SANDIA:TMPREF 100
SAS:SANDIA:TMPREF -100
Query Syntax: SAS:SANDIA:TMPREF?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:TMPREF?
Return Example: -1.000000e+02
12. SAS:SANDIA:BETA
Description: Sets the BETA parameter in SANDIA Mode.
Syntax: SAS:SANDIA:BETA <NRf+>
Parameter: <NRf+>
Example: SAS:SANDIA:BETA 0
SAS:SANDIA:BETA -2
Query Syntax: SAS:SANDIA:BETA?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:BETA?
Return Example: -2.000000e+00
13. SAS:SANDIA:FF
Description: Sets the fill factor in SANDIA Mode.
Syntax: SAS:SANDIA:FF <NRf+>
Parameter: <NRf+>
Example: SAS:SANDIA:FF 0.4
SAS:SANDIA:FF 0.95
Query Syntax: SAS:SANDIA:FF?
Return Parameter: <NRf+>
Query Example: SAS:SANDIA:FF?
Return Example: -2.000000e+00
14. SAS:SANDIA:IRR
Description: Sets the irradiation in SANDIA Mode.
Syntax: SAS:SANDIA:IRR <NR1>
Parameter: <NR1>
Example: SAS:SANDIA:IRR 1000
SAS:SANDIA:IRR 3000
Query Syntax: SAS:SANDIA:IRR?
Return Parameter: <NR1>
Query Example: SAS:SANDIA:IRR
Return Example: 1000
15. SAS:SANDIA:TMP
Description: Sets the temperature in SANDIA Mode.
Syntax: SAS:SANDIA:TMP <NRf+>
Parameter: <NRf+>
Example: SAS:SANDIA:TMP 100

Table of Contents