Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
1-4
Model 62150H-1000S
A620027 Slave Unit
(15kW)
A620028 Slave Unit
(15kW)
Output Ratings
Output Voltage
1
0-1000V
0-600V
0-1000V
Output Current
2
0-15A
0-25A
0-15A
Output Power
15000W
15000W
15000W
Voltage
Measurement
Range
3
200V / 1000V
120V / 600V
200V / 1000V
Accuracy
0.05% + 0.05%F.S.
0.05% + 0.05%F.S.
0.05% + 0.05%F.S.
Current
Measurement
Range
3
6A / 15A
10A / 25A
6A / 15A
Accuracy
0.1% + 0.1%F.S.
0.1% + 0.1%F.S.
0.1% + 0.1%F.S.
Output Noise &
Ripple
Voltage
Noise(P-P)
4
2550 mV
1500 mV
2550 mV
Voltage
Ripple(rms)
1950 mV
650 mV
1950 mV
Current
Ripple(rms)
5
270mA
450mA
270mA
Programming
Response Time
Rise Time:
50%F.S. CC Load
25 ms
30ms
25ms
Rise Time: No
Load
25 ms
30ms
25ms
Fall Time: 50%F.S.
CC Load
25 ms
30ms
25ms
Fall Time: 10%F.S.
CC Load
80 ms
100ms
80ms
Fall Time: No Load
3 s
1.2s
3s
Slew Rate Control
Voltage slew rate
range
6
0.001V/ms 40V/ms
0.001V/ms - 20V/ms
0.001V/ms - 40V/ms
Current slew rate
range
7
0.001A 0.1A/ms or
INF
0.001A/ms - 0.1A/ms,
or INF
0.001A/ms - 0.1A/ms,
or INF
Minimum transition
time
0.5 ms
0.5ms
0.5ms
1.3.1 Other Specifications
Table 1-2 lists the other specifications of the 62000H. Table 1-3 lists the other specifications
of the A620027 & A620028 models.

Table of Contents

Related product manuals