Remote Operation
Example: SAS:VOC 600
SAS:ISC 8
SAS:IMPp 5
SAS:VMPp 400
TRIG
6. SAS:PMPp
Description: Sets the PMPp in EN50530 Mode.
Syntax: SAS:VMPp <NRf+>
Example: Changes the PMPp to 1500.0 W.
SAS:PMPp 1500
Query Syntax: SAS:PMPp ?
Return Parameter: <NRf+>
Query Example: SAS:PMPp ?
Return Example: 1.500000e+03
7. SAS:VMPp
Description: Sets the VMPp in EN50530 Mode.
Syntax: SAS:VMPp <NRf+>
Example: Changes the VMPp to 500.0 V.
SAS:VMPp 500
Query Syntax: SAS:VMPp ?
Return Parameter: <NRf+>
Query Example: SAS:VMPp ?
Return Example: 5.000000e+02
8. SAS:TECH
Description: Sets the TECH in EN50530 Mode.
Syntax: SAS:TECH <NR1>
Parameter: CSI/TF
Example: SAS:TECH CSI
SAS:TECH TF
Query Syntax: SAS:TECH?
Return Parameter: CSI | TF
Query Example: SAS:TECH?
Return Example: CSI
9. SAS:IRR
Description: Sets the irradiation in EN50530 Mode.
Syntax: SAS:IRR <NR1>
Parameter: <NR1>
Example: SAS:IRR 1000
SAS:IRR 3000
Query Syntax: SAS:IRR?
Return Parameter: <NR1>
Query Example: SAS:IRR?
Return Example: 1000
10. SAS:SANDIA:IRRREF
Description: Sets the irradiation reference in SANDIA Mode.
Syntax: SAS:SANDIA:IRRREF <NR1>
Parameter: <NR1>
Example: SAS:SANDIA:IRRREF 1000
SAS:SANDIA:IRRREF 3000