151
No.
Error message on the
display
Possible cause Remedy
58 IO module 2 failed CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
59
VBC Profibus module
failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
60
Software version
operating module out-
of-date
Software update required.
Software update
Service
61
Software version QWD1
out-of-date
Software update required.
Software update
Service
62
Software version QWD2
out-of-date
Software update required.
Software update
Service
63
Software version QWD3
out-of-date
Software update required.
Software update
Service
64
Software version QWD4
out-of-date
Software update required.
Software update
Service
65
Software version DSP 1
out-of-date
Software update required.
Software update
Service
66
Software version DSP 2
out-of-date
Software update required.
Software update
Service
67
Software version IO
module 1 out-of-date
Software update required.
Software update
Service
68
Software version IO
module 2 out-of-date
Software update required.
Software update
Service
69
Software version VBC
ProfiNet out-of-date
Software update required.
Software update
Service
72
Robot communication
failed
CAN connection interrupted
between robot controller and
welding power source.
Switch machine Off and On
Check plug and connections
Service
73
No communication with
DSP
Interruption in the CAN bus of the
welding power source.
Check plug and connections
Check settings (set from automatic to
manual)
Service
180
Operating module - No
memory card found
No memory card or defective
memory card in the card slot of the
Premium operating module.
Change SD card
Service
181
Operating module
- Memory card not
formatted
Unformatted memory card, please
format memory card via PC/Laptop.
Please format SD card again
(FAT or FAT 32)
Service
182
Operating module - File
could not be opened/
found
Data on SD card cannot be read.
Check file on memory card
Use new memory card
Service