152
No.
Error message on the
display
Possible cause Remedy
183
Operating module
- Maximum text
number in language file
exceeded
Language file version newer than
machine (not compatible with
software).
Use other language file
Service
184
Operating module
- Invalid symbol in
language file
Language file version newer than
machine (not compatible with
software).
Use other language file
Service
185
Operating module -
RAM memory range for
language file exceeded
Language file version newer than
machine (not compatible with
software).
Use other language file
Service
186
Operating module - No
language found
No language file available on
memory card.
Load language file on the memory card.
Service
187
Operating module -
Error when transmitting
the SD-Min-limit values
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
188
Operating module -
Error when transmitting
the SD-Max-limit values
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
189
No enable from control
computer
Time of initialisation in control
computer exceeded (25 seconds).
Switch machine Off and On
Check software for compatibility
Service
190
Transmission error
logbook
An SD module logbook could not be
transmitted correctly.
Check SD card in SD module
Check plug and connections
Service
191
Unknown error in file
system
Access to SD card is not possible.
Check SD card
Check plug and connections
Service
192
Telegram subsequent
error
Error in data transfer.
Check SD card
Check plug and connections
Service
193
Transmission error from
control computer
Error in data transfer.
Check SD card
Check plug and connections
Service
194
Checksum error during
data receipt
Error in data transfer.
Check job data and then save job again
Service
195
Operating module -
Unknown machine type
Read error, old software.
Switch machine Off and On
Software update
Service
196 Overflow - receive buffer Error in data transfer.
Check SD card
Check plug and connections
Service
197 Read error in file Error in data transfer.
Check SD card
Check plug and connections
Service

Table of Contents