153
No.
Error message on the
display
Possible cause Remedy
198
Timeout during data
receipt
Error in data transfer.
Check SD card
Check plug and connections
Service
200
SD module - Required
logbook not found
Logbook deleted.
Call up logbook file again
Service
201
SD module Logbook is
empty
No data available in the logbook.
Check SD settings
Start welding process
Service
202
SD module Logbook
entry not found
Request of a non-existent logbook
entry
Call up logbook file again
Service
203
SD module Error in
logbook
Logbook format error
Repeat logbook backup
Service
204
SD module sends
unknown error message
Software out-of-date.
Software update
Service
205
Operating module -
Error when transmitting
the SD configuration
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
206
Operating module - SD
module not available.
Selected SD module not available or
connected.
Check plug and connections
Check SD module
Service
207
Sector size in data flash
exceeded.
File size exceeded.
File not compatible with software.
Service
210
SD module Job not
available
Job not available in SD module
Check job selection
Create job
Service
211
SD module Job has a
wrong checksum
Job not available in SD module or
faulty.
Job format out-of-date.
Check job selection
Create job
Service
212
SD module- No memory
card found
Memory card not available in
SD module, faulty or improperly
formatted.
Insert SD card
SD card defective
Service
213
SD module - Memory
card write-protected
Memory card in SD module write-
protected.
Check SD card
Change SD card
Service
214
SD module - Memory
card full
Data volume limit reached.
Change SD card
Service
250
QWD1 No controller
data available
Error occurs with push/pull torches.
Software out-of-date.
Software update
Service
251
QWD2 No controller
data available
Error occurs with push/pull torches.
Software out-of-date.
Software update
Service
252
QWD3 No controller
data available
Error occurs with push/pull torches.
Software out-of-date.
Software update
Service