Setup procedures (part 4)
8-2 9390 Reference manual
Scan table automatic scanning start
Setup code 11
This procedure sets the time delay to resume automatic
scanning after the receipt of a call.
When you do not touch any button or knob for longer than
this delay time, the transceiver automatically starts scanning.
If you have set up any of the three scan tables for ALE
scanning, it uses the scan table last used in scanning. If you
have not set up any scan table for ALE scanning, it uses scan
table 1.
You can switch automatic scanning:
on with a 1–10 minute time delay
off.
To switch automatic scanning on or off:
Action Notes
1.
Repeatedly press
Mode
until you see the display
for Setup mode.
The display shows:
EXIT
SETUP MENU
1- Scan-
2–Call
ENTER
3–Config
4–More
1/2
2.
Enter 11
numeral
buttons
Example of the display:
EXIT
Auto Scan Setup
Time: Off
Autoscan is Off