Setup procedures (part 4)
9390 Reference manual 8-25
Action Notes
7.
Enter the low frequency
numeral
buttons
Set a value in the range
300–2800Hz.
To cancel an existing setting
and leave the low frequency
unset, enter 0.
Leave the low frequency unset
if you want this tone call group
to use a single frequency.
8.
To save your changes,
press
F2
For example, a low frequency
of 550Hz looks like this:
EXIT PROGRAM
Hi: 1 4 0 0 Hz Low: 5 5 0 Hz
Tone Pair: 3
9.
Do you want to set up
another tone call group?
Yes
Return to
Step 3.
No
Step 10.
10.
To return to Channel
mode, press three times
F1
Example of the display:
USB
HI
RF–ON
Rx.
422
Radphone
Pwr
4,128
4,420