Setup procedures (part 1)
5-20 9390 Reference manual
Action Notes
3.
Press
F2
The display shows the day and
time that the calibration was
last set:
EXIT
TIME CALIBRATION
ENTER
Last 04/06/96 18:04
+010 sec/month
+--
4.
To change the calibration
setting, rotate
Select
The calibration range is -150 to
+310 seconds/month in steps of
10.
As you change the value, the
slider moves at the bottom of
the screen—as displayed
above.
5.
To save your change,
press
F2
The display shows:
EXIT
TIME SETUP MENU
ENTER
1– Set
2–Calib
6.
To return to Channel
mode, press twice
F1
Example of the display:
USB
HI
RF–ON
Rx.
422
Radphone
Pwr
4,128
4,420