Changing the setup options
9480 HF SSB transceiver Error! Main Document Only.-7
PTT timer
This facility stops the transceiver from being left on in the transmit state. If the
transmit time exceeds the PTT timer setting, the transceiver reverts to the receive
mode and an error message is displayed.
The timer is set at the factory to 10 minutes. You may turn this facility off, or vary the
time between 5 and 35 minutes in five minute intervals.
Step Action… Display shows… Remarks…
1.
Turn the
transceiver off
and move the
front panel link to
position 1.
No display. Before moving the link,
note its original position.
Refer to the procedure on
page 8-3.
2.
Hold down
Tune
and press
On/Off
Hold the Tune button
down until the display
shows
This turns on the
transceiver in PTT timer
setup mode.
3.
Press
Volume
The PTT ‘time out’ time
can be changed from 5 to
35 minutes.
Press either the
or
button to increase
or decrease the time.
Stop at the setting you
require.