NGT—Checks and adjustments
158 NGT Transceiver System Technical Service Manual
Returning to Normal mode
To return the transceiver to Normal mode:
1 Switch off the transceiver.
1 Remove:
• link 11 on the Microprocessor PCB in the junction box (see drawing 08-05317
and Figure 25 on page 154), or
• link A on the Application Processor Handset I/F 3 V PCB in the 2011 (see
drawing 08-05987 and Figure 26 on page 155)
• link A on the Application Processor Handset & Data I/F PCB in the 2012 (see
drawing 08-06260 and Figure 27 on page 155)
1 Switch on the transceiver.
The transceiver is now in Normal mode and normal operation can resume.