NGT—Checks and adjustments
174 NGT Transceiver System Technical Service Manual
NOTE
Links X1 and X2 on the oscillator PCB (drawing 08-05963) may be
joined to lower the frequency if the trimmer does not have enough
range.
Approximate link settings are:
X1: 200 Hz
X2: 400 Hz
X1 + X2: 600 Hz