Appendix B: Specifications P/N 709C011801 Page 138
DRAFT
Environmental, Standards and Optical
Environmental
Operating Temperature
0°C to +50°C (32°F to 122°F)
Storage
-20°C to 85°C (-4°F to 185°F)
Standards and Approvals
Laser Safety FDA/CE 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice no.
50 and IEC 60825-1
EMC CE EN 301 489, EN55022, EN 61000
FCC 47 CFR Part 15, 22, 24, 27
Safety UL 60950
IEC 60825-1:2007
IEC 60825-2:2010
CAN/CSA-C22.2 No.60950-1-03
Fire Safety UL 2043 (applicable for Access Unit only)
Optical
Optical Output Power < 9 dBm
Max. Optical Budget 5 dB
Optical Connector
OIM: Female MTP
®
connector;
RAU: LC APC SM
Fiber Type
Corning
®
SMF-28
®
fiber or compatible
Wavelength
1310 ± 10 nm (@ 25
C)
Maximum Distance
(Headend to Remote)
2 km (SMF)