Chapter 8 TroubleshootingVP3000
472
ID No.
Warning Name
Descriptions
154
Battery low voltage
(RtLv)
Insufficient voltage of the external battery
Action and Reset
Action Condition
The battery voltage is lower than 2.4 V
Action Time
1 second
Warning Setting Parameter
Pr. J6-00
0: No warning
1: Warning after power on
2: Warning each hour
3: Warning each day
Reset Method
Immediately resets or automatically clears when the level returns to 2.4V
Reset Condition
Immediately resets or automatically clears when the level returns to 2.4V
Record
Yes
Cause
Corrective Actions
Insufficient battery voltage
Replace with a new battery.
Battery detection abnormal
If the warning cannot be cleared after replacing the battery and the warning still
exists after restarting the drive, return to the factory for repair.