Chapter 10 Accessories | VP3000
645
NET LED
LED Status
Indication
Corrective Action
Green light
ON
Normal status
--
Red light ON
CMC-PD01 is not connected to
PROFIBUS DP bus
Connect CMC-PD01 to PROFIBUS DP bus.
Red light
flashes
Invalid PROFIBUS communication
address
Set the PROFIBUS address of CMC-PD01
between 1–125 (decimal)
Orange light
flashes
CMC-PD01 fails to communicate
with AC motor drive
Switch off the power and check whether CMC-
PD01 is correctly and normally connected to AC
motor drive
Table 10-12