Chapter 10 Accessories | VP3000
651
Environment
ESD (IEC 61800-5-1, IEC 61000-4-2)
EFT (IEC 61800-5-1, IEC 61000-4-4)
Surge Test (IEC 61800-5-1, IEC 61000-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6)
Operation: -10–50ºC (temperature), 90% (humidity)
Storage: -25–70ºC (temperature), 95% (humidity)
Shock / Vibration
Resistance
International standards: IEC61800-5-1, IEC60068-2-6 / IEC61800-5-1,
IEC60068-2-27
⚫ Installation
Connecting CMC-EIP01 to Network
1. Turn off the power of the drive
2. Open the cover of the AC motor drive
3. Connect a CAT-5e network cable to the RJ45 port on the
CMC-EIP01, as shown in the figure on the right.
Positive pole for
data transmission
Negative pole for
data transmission
Negative pole for
data receiving
Positive pole for
data receiving
⚫ VP3000 Communication Parameters Settings for Connecting to Ethernet
When the VP3000 is connected to an Ethernet network, set up the communication parameters
for it according to the table below. The Ethernet master is only able to read and write the
frequency words and control word of VP3000 after the communication parameters are set.
Delta drive decoding method
EtherNET IP Configuration