EasyManua.ls Logo

DGSHAPE DE-3 - 1025-0000 (RML-1) a Wrong Command Is Detected; 1029-0000 the Spindle Experienced an Overload

DGSHAPE DE-3
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When Using Software Other Than Dr. Engrave Plus
Contact the software manufacturer to check whether the software is compatible with this machine.
"1025-0000" (RML-1) A wrong command is detected.
Level 1
Error Situation/Cause
There is a problem with the engraving data.
The data transfer has failed due to the computer being under a high load.
Action
Procedure
A
Turn the [Dial] and select [Continue] or [CancelJob].
B
Press [ENTER/PAUSE].
C
Send the engraving data to this machine again.
" P. 54 "Step 5: Starting Engraving"
When Using Software Other Than Dr. Engrave Plus
Contact the software manufacturer to check whether the software is compatible with this machine.
"1029-0000" The spindle experienced an overload.
Level 2
Error Situation/Cause
The tool is worn.
A workpiece that cannot be engraved by this machine is being used.
The engraving parameters are too strict.
The Z origin has been set incorrectly.
Responding to an Error Message
147
Chapter 6 Appendix

Table of Contents