Error Info/Description Remedy
2155 · Step motor X-axis
overcharge
· Step motor X-axis
blocked/moves too heavy
· Step motor X-axis
defective
· Control defective
· Eliminate the blocking/rough
running
· Replace step motor X-axis
· Replace the control
2156 · Step motor X-axis
excess temperature
· Step motor X-axis
moves too heavy
· Step motor X-axis
defective
· Control defective
· Eliminate rough running
· Replace step motor X-axis
· Replace the control
2162 · Step motor X-axis
IDMA Autoincrement
· Malfunction
· Switch the machine off and on
again
2201 · Step motor Y-axis
timeout reference
· Cable to the reference switch
faulty
· Reference switch defective
· Replace the cable
· Replace the reference s witch
2202 · Step motor Y-axis
Current supply fault
· Step motor Y-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Eliminate the blocking
· Check /
Replace the encoder cable
· Replace step motor Y-axis
2252 · Step motor Y-axis
excess current
· Step motor Y-axis defective
· Control defective
· Replace step motor Y-axis
· Replace the control
2253 · Step motor Y-axis
excess voltage
· Too high mains voltage
· Check the mains voltage
2255 · Step motor Y-axis
overcharge
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
· Control defective
· Eliminate the blocking/rough
running
· Replace step motor Y-axis
· Replace the control
2256 · Step motor Y-axis
excess temperature
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
Control defective
· Eliminate the blocking/rough
running
· Replace step motor Y-axis
· Replace the control
2262 · Step motor Y-axis
IDMA Autoincrement
·Malfunction
·Switchthemachineoff
and on again
3