EasyManua.ls Logo

ECKELMANN Case Controller UA 4 E Series - Page 354

ECKELMANN Case Controller UA 4 E Series
466 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware V3.13
21.04.2021
354/466
Menu 1-7 Cooling Zone 2
COOLING 2 XXXXX
Cooling XXX Displays current OFF/ON status of cooling
op.deg. Z 2 XX % Displays current valve opening degree Zone 2
OD med. 24h XX % Displays mean valve opening degree Zone 2 for past day
Temp. R4.2 XXX °C Displays current room air temperature Input Z71/Z72
Setpoint R4.2 XXX °C Displays room air temperature setpoint for comparison
Hystersis R4.2 XXX K Displays room air temperature hysteresis setpoint; shown only when on-off control
is set (Menu 2-1-2)
SH Z 2 XXX °C Displays current superheat temperature Zone 2
sup air ctrl XXX Displays current OFF/ON status of supply or room air control
MOP op. XXX Displays OFF/ON setpoint of MOP mode
Status hand XXX Status manual shutdown (ON/OFF)
Menu 1-8 Defrost Zone 2
DEFROST 2 XXXXX
Counting Rate X Displays setpoint for time during which evaporator defrost termination temperature
may be within band around 0°C before defrost counter counts down
Defrost Counter X Displays count for number of defrost cycles to be skipped
Defrost XXX Displays current OFF/ON status of Defrost Relay 2
Temp. R1.2 XXX °C Displays current evaporator defrost termination temperature Input Z81/Z82
Def. End. Tmp. XXX °C Displays defrost termination temperature setpoint for comparison
Wait Time XX m Displays waiting time setpoint
Drip Time XX m Displays drip time setpoint
Last Defrst XX hh:mm Displays time (day, time of day) of last defrost cycle started
Menu 1-9 Fan Zone2
FANS 2 XXXXX
Fans XXX Displays current fan status
Temp. R1.2 XXX °C Displays current evaporator defrost termination temperature Input Z81/Z82
Fan Delay XXX °C Displays fan start temperature setpoint

Table of Contents

Related product manuals