SET CLASS <n> set programmable alarm classifications
SET CMD <n> set programmable commands
SET COM set local comm port configuration
SET DATE <mm/dd/yy> set date where mm = month, dd = date, yy = year
SET DEFAULTS set system default parameters
SET EFF set Energy Management parameters
SET EMAIL set IP DNS server, SMTP Server, and return mail addresses
SET GATEWAY set GATEWAY port communications data rate
SET INFO <n> configure information pages
SET LED <n> turn LED on
SET LIMITS <tn> set channel alarm limits
SET MAIL send mail to users
SET MODE modify configuration of TL1 port settings
SET PERIODS <tn> set time periods
SET PHONE set user phone numbers
SET PROGRAM <tn> configure control programs
SET REPORT set system alarm reporting parameters
SET RLY <n> energize relay
SET SEQUENCE set AC & Standby sequencer parameters
SET STATUS <n> configure status page
SET SYSTEM configure all settings
SET TIME <hh:mm:ss> set time where hh = hours, mm = minutes, ss = seconds
SET TIMEOUT <n> set user timeout
SET UNIT set unit name and number
SET USERS <n> configure a user
SET VI set Plant Voltage and Load settings
SET VORTEX configure Vortex Power System settings
SNMP GET <comm name> set the SNMP GET community name
SNMP OFF disable SNMP access
SNMP ON enable SNMP access
SNMP SET <comm name> set the SNMP SET community name
TRAPS ADD <n> add a new SNMP Trap recipient to the list of TRAP hosts
TRAPS DELETE <n> remove a host address from the list of TRAP hosts
TRAPS OCCURRED disable/enable the systems ability to send SNMP Occurred
Alarm TRAPS
TRAPS OFF disable the systems ability to send SNMP TRAPs
TRAPS ON enable the system to send SNMP TRAPs
TRAPS PERSISTENT disable/Enable the systems ability to send SNMP Persistent
Alarm TRAPS or set the Persistent Alarms reporting
interval
TRAPS RETIRED disable/enable the systems ability to send SNMP Retired
Alarm TRAPS
TRAPS VERSION <V1|V2> change the version of SNMP TRAPs sent by the system
ALARMS VORTEX list active Power System alarms
ALARMS VORTEX LVD list active LVD alarms
ALARMS VORTEX MCA list active MCA alarms
ALARMS VORTEX PCU<n> list active PCU alarms
ALARMS VORTEX SHUNT list active SHUNT alarms
ALARMS VORTEX SUBSYSTEM list active subsystem type alarms
ALARMS VORTEX SYSTEM list active system type alarms
DOWNLOAD VORTEX dump Vortex Power System configuration
using XMODEM protocol

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson LMS1000 and is the answer not in the manual?

Emerson LMS1000 Specifications

General IconGeneral
BrandEmerson
ModelLMS1000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals