User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-87
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
PRCONFIG VORTEX list settings and equipment inventory
PRCONFIG VORTEX INVENTORY list equipment inventory
PRCONFIG VORTEX SETTINGS list settings
SCAN VORTEX list present status of Vortex Power System
SCAN VORTEX LVD list present status of LVD circuits
SCAN VORTEX MCA list present status of MCA
SCAN VORTEX PCU<n> list present status of specified PCU
SCAN VORTEX SUBSYSTEM list present status of subsystem data
SCAN VORTEX SYSTEM list present status of system data
SET VORTEX INTERFACE Enable/Disable Vortex interface
SET VORTEX LVD<n<t>> DISCONNECT set specified LVD disconnect voltage settings
SET VORTEX LVD RECONNECT set LVD reconnect voltage setting
SET VORTEX MESSAGE MCA set MCA custom message
SET VORTEX MESSAGE PCU<n> set specified PCU custom message
SET VORTEX PASSWORD set MCA logon password
SET VORTEX PCU<n> turn specified PCU On or Off
SET VORTEX SYSTEM 25APLACES set system number of 25A Places
SET VORTEX SYSTEM 50APLACES set system number of 50A Places
SET VORTEX SYSTEM 100APLACES set system number of 100A Places
SET VORTEX SYSTEM 200APLACES set system number of 200A Places
SET VORTEX SYSTEM 50%BATONDISCH set system 50% Battery On Discharge alarm
SET VORTEX SYSTEM BATONDISCH set system Battery On Discharge alarm
SET VORTEX SYSTEM CALVOLT set system calibration voltage
SET VORTEX SYSTEM CURLIMIT set system current limit
SET VORTEX SYSTEM FACTORYCAL set system cal. voltage to factory default
SET VORTEX SYSTEM FLTVOLT set system float voltage
SET VORTEX SYSTEM HIVLTALM1 set system High Voltage 1 Alarm
SET VORTEX SYSTEM HIVLTALM2 set system High Voltage 2 Alarm
SET VORTEX SYSTEM HVS set system High Voltage Shutdown
SET VORTEX SYSTEM INVENTORY reset the system equipment inventory
SET VORTEX SYSTEM MODE set Power System mode
SET VORTEX SYSTEM NAGTIMER set system ACO timer
SET VORTEX SYSTEM OVRCURRENT set system Overcurrent alarm
SET VORTEX SYSTEM TEMPCOMP set system Temperature compensation voltage
SET VORTEX SYSTEM TSTEQVOLT set system test/equalize voltage
SET VORTEX SUBSYSTEM CALVOLT set subsystem calibration voltage
SET VORTEX SUBSYSTEM FACTORYCAL set subsystem cal. voltage to factory default
SET VORTEX SUBSYSTEM HIVALM set subsystem High Voltage alarm
SET VORTEX SUBSYSTEM LVALM set subsystem Low Voltage alarm
SET VORTEX SUBSYSTEM OVRCURRENT set subsystem Overcurrent alarm
UPLOAD VORTEX configure Vortex Power System by
uploading file using XMODEM
protocol
Programmed Command: Command Strings:
where: <> anything enclosed in brackets is optional
n is a valid number
t is a type A, B, E, F, G, L, R for Analog, Binary,
Energy Management, Function, Group, LED or Relay
is A or B for Vortex LVD settings