• Enhanced the Thermal Expansion Coefficient in the Petroleum Measurement software application to allow
values down to 0.000023 per deg F
• Enhanced the slope/offset equation in the Concentration Measurement software application to allow the
offset to correct for negative concentration
• Configuration files are successfully restored and transferred
• Outputs can be fixed through the local display through active tests
• Smart Meter Verification run from the Startup Tasks menu works without issues
• Enhanced ProLink III support for downloading services files
• Improved the display to show user-configured Special concentration unit labels for the Concentration
Measurement software application
Feature additions:
• Added support for the HPV10P sensor
• Enhanced the RS-485 communications port when used with Disable ASCII mode to support baud rates less
than 38400
• Enhanced the Totalizer Log to record the value of the totalizer before it is reset
• Clarified Russian and Chinese translations for local display menus
• Enhanced the local display to Recommended Compensation values
• Enhanced Advanced Phase Measurement (APM) for Phase II
• Enhanced API support so that API 12.2.2 and API 12.2.5 are available for E tables
• Enhanced the Audit Trail to distinguish between Modbus/485 (User) and Modbus/USB (Service) ports
• Enhanced the display to show Flow Verification Zero
• Improved responsiveness of the local display button
• Added support for user-configurable totalizer rollover behavior
• Enhanced save all service files operation to save the Totalizer log
• Added support for Totalizer rollover for both Weights & Measures and OIML when in secured mode with 0
flow
• Access to APM Contract Total functionality available without any licenses
• Changed default PV/SV/TV/QV to MF/Dens/VF/Temp
• Modified API tables B, C, and E to reduce error under certain conditions so they are now approved for use
as shown on the certificate TCV8519 Rev2
October 2017, version 2.0
Document revision 20025166, Rev. AB
Software improvements:
• Corrected both Russian and Japanese strings on the local display
• Enhanced local display to show the hardware revision level
• Support added for running zero verification in secure mode
Software history (NAMUR recommendation NE53) Configuration and Use Manual
March 2019 MMI-20025166
352 Micro Motion Model 5700 Transmitters with Configurable Outputs