In this product, Gas Density Correction is enabled for all sensors Order ETO 27577 if you would like to
disable Gas Density Correction.
Added Unremediated Mass Flow and Unremediated Volume flow, which can be assigned to the
Frequency Outputs
Added Unremediated Mass Flow to the data historian files when APM PG is enabled
Added new density and flow equation extensions for the CMFS sensors
Changed the rebooting option on the local display to reboot both the core processor and the Model
5700 transmitter
Added coil 100 so a user can start-resume or pause a batch with a single coil
March 2019, version 3.0
Document revision 20025166, Rev. AC
Feature additions:
Net Oil Calculations (NOC) with multi-well functionality is available with purchase of license.
Manual Mode for APM is available with purchase of a license.
APM Remediation is available for all output types.
Gas Linearization function is available with purchase of a license.
Added Energy Flow calculation
Added constant batch mode application, a simplified batch screen flow in addition to standard batch
screens. The transmitter remains in constant batch mode until a password is entered to exit mode.
Added new batch features including preset inventories, batch inhibit, batch end, inhibit batch flow, and
inhibit batch total coils.
Sensor Simulation and menu enable/disable parameters added to HART.
Added warning for customers if the core has an ETO installed when upgrading.
Added additional options for starting and stopping totalizers based on events like reaching a specific total,
or the occurrence of a fault condition.
Added HART parameters for Installation Verification and Measurement Verification.
Added additional parameters (device tag, timestamp) to the printer test ticket.
Added support for Tantalum sensors and Tantalum sensor features.
New PVs are available for assignment to the mA Output (MAO):
Calorific Value
Energy Flow
Unremediated Mass Flow
Unremediated Volume Flow
Unremediated Density
TRM Liquid Flow
External Density
Software history (NAMUR recommendation NE53) Configuration and Use Manual
March 2019 MMI-20025166
354 Micro Motion Model 5700 Transmitters with Configurable Outputs