Diagnostics and troubleshooting Proline Promass E 500 PROFIBUS PA
216 Endress+Hauser
Diagnostic information Remedy instructions
No. Short text
332 Writing in HistoROM backup failed Replace user interface board
Ex d/XP: replace transmitter
Measured variable status
Quality Bad
Quality substatus Maintenance alarm
Coding (hex) 0x24 to 0x27
Status signal F
Diagnostic behavior Alarm
Influenced measured variables
• Oscillation amplitude 1
• Oscillation amplitude 2
• Signal asymmetry
• Carrier mass flow
• Carrier pipe temperature
• Target corrected volume flow
• Carrier corrected volume flow
• Concentration
• Oscillation damping 1
• Oscillation damping 2
• Density
• Oil density
• Water density
• Dynamic viscosity
• Sensor electronic temperature (ISEM)
• Empty pipe detection option
• GSV flow
• GSV flow alternative
• Kinematic viscosity
• Low flow cut off option
• Mass flow
• Oil mass flow
• Water mass flow
• HBSI
• NSV flow
• NSV flow alternative
• External pressure
• Exciter current 1
• Exciter current 2
• Oscillation frequency 1
• Oscillation frequency 2
• S&W volume flow
• Reference density
• Reference density alternative
• Corrected volume flow
• Oil corrected volume flow
• Water corrected volume flow
• Oscillation damping fluctuation 1
• Oscillation damping fluctuation 2
• Frequency fluctuation 1
• Frequency fluctuation 2
• Target mass flow
• Carrier volume flow
• Target volume flow
• Temp. compensated dynamic viscosity
• Temp. compensated kinematic viscosity
• Temperature
• Status
• Volume flow
• Oil volume flow
• Water volume flow
• Water cut
Diagnostic information Remedy instructions
No. Short text
361 I/O module 1 to n faulty 1. Restart device
2. Check electronic modules
3. Change I/O Modul or main electronics
Measured variable status
Quality Bad
Quality substatus Maintenance alarm
Coding (hex) 0x24 to 0x27
Status signal F
Diagnostic behavior Alarm
Influenced measured variables
• Oscillation amplitude 1
• Oscillation amplitude 2
• Signal asymmetry
• Carrier mass flow
• Carrier pipe temperature
• Concentration
• Measured values 1
• Measured values 2
• Measured values 3
• Oscillation damping 1
• Oscillation damping 2
• Density
• Dynamic viscosity
• Sensor electronic temperature (ISEM)
• Empty pipe detection option
• Kinematic viscosity
• Low flow cut off option
• Mass flow
• HBSI
• External pressure
• Exciter current 1
• Exciter current 2
• Oscillation frequency 1
• Oscillation frequency 2
• Reference density
• Corrected volume flow
• Oscillation damping fluctuation 1
• Oscillation damping fluctuation 2
• Frequency fluctuation 1
• Frequency fluctuation 2
• Target mass flow
• Temp. compensated dynamic viscosity
• Temp. compensated kinematic viscosity
• Temperature
• Status
• Volume flow