Proline Promass E 500 PROFIBUS PA Installation
Endress+Hauser 31
ø 20…70
( 0.79…2.75)ø
~102 (~ 4.0)
4 x
SW 10
3 x
TX 25
A0029051
 12 Unit mm (in)
Wall mounting
Required tools:
Drill with drill bit ⌀ 6.0 mm
149 (5.85)
211 (8.31)
=
5.8 (0.23)
17 (0.67) =
L
5.8 (0.23)
A0029054
 13 Engineering unit mm (in)
L Depends on order code for "Transmitter housing"
Order code for "Transmitter housing"
Option A, aluminum, coated: L = 14 mm (0.55 in)
Option D, polycarbonate: L = 13 mm (0.51 in)
1. Drill the holes.
2. Insert wall plugs into the drilled holes.
3. Screw in the fixing screws slightly.
4. Fit the transmitter housing over the fixing screws and mount in place.