Proline Promass E 500 PROFIBUS PA Installation
Endress+Hauser 29
1
1
2
2
1
1
5 (0.2) min. 15 (0.6)
SW 2.5
M3
A0029799
1 Cover borehole for the securing screw
2 Securing screw to lock the cover
6.2 Installing the measuring instrument
6.2.1 Required tools
For transmitter
For mounting on a post:
• Proline 500 – digital transmitter
• Open-ended wrench AF 10
• Torx screwdriver TX 25
• Proline 500 transmitter
Open-ended wrench AF 13
For wall mounting:
Drill with drill bit ⌀ 6.0 mm
For sensor
For flanges and other process connections: Use a suitable mounting tool.
6.2.2 Preparing the measuring instrument
1. Remove all remaining transport packaging.
2. Remove any protective covers or protective caps present from the sensor.
3. If present, remove transport protection of the rupture disk.
4. Remove stick-on label on the electronics compartment cover.
6.2.3 Mounting the measuring device
L
WARNING
Danger due to improper process sealing!
‣
Ensure that the inside diameters of the gaskets are greater than or equal to that of the
process connections and piping.
‣
Ensure that the seals are clean and undamaged.
‣
Secure the seals correctly.