EasyManua.ls Logo

Endress+Hauser Proline Promass E 500 - 16.13 Application Packages

Endress+Hauser Proline Promass E 500
300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass E 500 PROFIBUS PA Technical data
Endress+Hauser 289
Tests and certificates
External standards and
guidelines
EN 60529
Degrees of protection provided by enclosures (IP code)
IEC/EN 60068-2-6
Environmental influences: Test procedure - Test Fc: vibrate (sinusoidal).
IEC/EN 60068-2-31
Environmental influences: Test procedure - Test Ec: shocks due to rough handling,
primarily for devices.
EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory
use - general requirements
EN 61326-1/-2-3
EMC requirements for electrical equipment for measurement, control and laboratory use
NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control
equipment
NAMUR NE 32
Data retention in the event of a power failure in field and control instruments with
microprocessors
NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters
with analog output signal.
NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
NAMUR NE 80
The application of the pressure equipment directive to process control devices
NAMUR NE 105
Specifications for integrating fieldbus devices in engineering tools for field devices
NAMUR NE 107
Self-monitoring and diagnosis of field devices
NAMUR NE 131
Requirements for field devices for standard applications
NAMUR NE 132
Coriolis mass meter
ETSI EN 300 328
Guidelines for 2.4 GHz radio components.
EN 301489
Electromagnetic compatibility and radio spectrum matters (ERM).
16.13 Application packages
Many different application packages are available to enhance the functionality of the
device. Such packages might be needed to address safety aspects or specific application
requirements.
The application packages can be ordered with the device or subsequently from
Endress+Hauser. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.
Detailed information on the application packages:
Special Documentation →  292
Diagnostic functionality Order code for "Application package", option EA "Extended HistoROM"
Comprises extended functions concerning the event log and the activation of the measured
value memory.