Technical data Proline Promass E 500 PROFIBUS PA
288 Endress+Hauser
Hygienic compatibility 3-A approval
Only measuring instruments with the order code for "Additional approval", option LP
"3A" have 3-A approval.
The 3-A approval refers to the measuring instrument.
When installing the measuring instrument, ensure that no liquid can accumulate on
the outside of the measuring instrument.
A remote display module must be installed in accordance with the 3-A Standard.
Accessories (e.g. heating jacket, weather protection cover, wall holder unit) must be
installed in accordance with the 3-A Standard.
Each accessory can be cleaned. Disassembly may be necessary under certain
circumstances.
EHEDG-tested
Only devices with the order code for "Additional approval", option LT "EHEDG" have been
tested and meet the requirements of the EHEDG.
To meet the requirements for EHEDG certification, the device must be used with process
connections in accordance with the EHEDG position paper entitled "Easy cleanable Pipe
couplings and Process connections" (www.ehedg.org).
To meet the requirements for EHEDG certification, the device must be installed in a
position that ensures drainability.
FDA
Food Contact Materials Regulation (EC) 1935/2004
Observe the special installation instructions
Certification PROFIBUS PROFIBUS interface
The measuring device is certified and registered by the PNO (PROFIBUS
Nutzerorganisation e.V./PROFIBUS User Organization). The measuring system meets all
the requirements of the following specifications:
Certified according to PA Profile 3.02
The device can also be operated with certified devices of other manufacturers
(interoperability)
Pressure Equipment
Directive
With the marking
a) PED/G1/x (x = category) or
b) PESR/G1/x (x = category)
on the sensor nameplate, Endress+Hauser confirms compliance with the "Essential
Safety Requirements"
a) specified in Annex I of the Pressure Equipment Directive 2014/68/EU or
b) Schedule 2 of Statutory Instruments 2016 No. 1105.
Devices not bearing this marking (without PED or PESR) are designed and manufactured
according to sound engineering practice. They meet the requirements of
a) Art. 4 Para. 3 of the Pressure Equipment Directive 2014/68/EU or
b) Part 1, Para. 8 of Statutory Instruments 2016 No. 1105.
The scope of application is indicated
a) in diagrams 6 to 9 in Annex II of the Pressure Equipment Directive 2014/68/EU or
b) Schedule 3, Para. 2 of Statutory Instruments 2016 No. 1105.
Radio approval The measuring device has radio approval.
For detailed information on the radio approval, see the Special Documentation
→  292
Additional certification CRN approval
Some device versions have CRN approval. A CRN-approved process connection with a CSA
approval must be ordered for a CRN-approved device.

Table of Contents