Confidential
2. Release the hooks (x2) on the bottom of the printer. (See Fig. 9-24.)
3. Lift the Housing Front Left slightly and release the ribs (x2) and dowel (x1),
and remove the Housing Front Left while avoiding the lever of the
Electromagnetic Plunger from the hole of the Housing Front Left.
Figure 9-24. Removing the Housing Front Left
9.4.2.10 Panel Unit
Parts/Components need to be removed in advance:
ADF Unit/Scanner Unit/Decoration Plate Left Upper Sub/Paper Guide Top Assy/
Upper Housing/Decoration Plate Left Upper
Removal procedure
1. Remove the screws (x2) that secure the Panel Unit.
Figure 9-25. Removing the Panel Unit (1)
Housing Front Left
Hook
Bottom
C.B.P. 3x10 (6±1Kgfcm)
Dowel
Rib
Frame
Hole
C H E C K
P O I N T
This section describes the disassembly/reassembly procedures of the
Panel Unit for Artisan 837/PX830FWD.
The disassembly/reassembly procedures for Artisan 730/PX730WD/
TX730WD differ from those for Artisan 837/PX830FWD, therefore,
see
"9.4.2.18 Panel Unit" (p.311) for the procedures.
C.B.P. 3x10 (6±1Kgfcm)
Panel Unit
Upper Housing
Dowel & positioning hole

Table of Contents