Disassembly/assembly 311
Confidential
8. While lifting the Upper Housing, pull out the Panel FFC from the hole of the
Upper Housing and remove the Upper Housing.
Figure 9-46. Removing the Upper Housing (5)
9. Remove the Panel Unit from the Upper Housing. (See "9.4.2.18 Panel Unit"
(p.311).)
9.4.2.18 Panel Unit
Parts/Components need to be removed in advance:
Scanner Unit/Left Housing/Paper Guide Top Assy
Removal procedure
1. Remove the screw (x1) and release the grounding wire.
(See 9.4.2.17 Upper Housing Step1 (p.309).)
2. Open the Panel Unit. (See Fig. 9-42 (p.310).)
3. Release the hook (x1) on the rear of the Panel Unit, and remove the Panel
Rear Cover. (See
9.4.2.17 Upper Housing Step3 (p.310).)
4. Peel off the Panel FFC and the ferrite core that are secured with the double-
sided tape, and disconnect the Panel FFC from the connector on the Panel
Unit. (See
9.4.2.17 Upper Housing Step4 (p.310).)
5. Pull out the ferrite core from the Panel FFC.
(See 9.4.2.17 Upper Housing Step5 (p.310).)
6. Remove the screws (x2) that secure the Right Hinge.
Figure 9-48. Removing the Panel Unit (1)
Tighten the screws in the order shown in Fig. 9-44.
Secure the Panel FFC and ferrite core to the Panel Shield Plate
with double-sided tape. (See
Fig. 9-43 (p.310).)
Fold the Panel FFC at the fold line, and route it along the
marking on the Panel Shield Plate.
Figure 9-47. Routing the Panel FFC
A D J U S T M E N T
R E Q U I R E D
After removing/replacing the Upper Housing, make the specified
adjustments. (See
"9.5 Adjustment" (p.321).)
Upper Housing
Hole of Upper Housing
Panel FFC
Panel Unit
Marking
C H E C K
P O I N T
This section describes the disassembly/reassembly procedures of the
Panel Unit for Artisan 730/PX730WD/TX730WD.
The disassembly/reassembly procedures for Artisan 837/
PX830FWD differ from those for Artisan 730/PX730WD/
TX730WD, therefore, see
"9.4.2.10 Panel Unit" (p.302) for the
procedures.
Panel Unit
Right Hinge
C.B.P. 3x10 (black) (6±1Kgfcm)