Symbol definitions
]
= CR/LF (carriage return/line feed)
}
or ¦
=
Carriage return (no line feed, hex 0D)
= Space
E
or W
= Escape
X(
=
0
=disabled/unassigned/off/unmuted
1=enabled/assigned/on/muted
X1)
= Configuration type
0 = IP Config (ip.cfg)
2 = Box specific parameters (box.cfg)
X1!
= Firmware version number
X1@
= Device name (63 characters, max)
Must comply with internet host name
standards.
X1#
= Day, date, and time
(Day,•MM•DD•YY-HH:MM:SS)
X1$
= Time zone acronym (2 to 6 letters)
X1%
= Greenwich Mean Time (GMT) offset value:
-12:00 to 14:00. Represents hours
and minutes (HH:MM) offset from GMT
including the time zone name.
X1^
= IP address in dotted decimal notation
(xxx.xxx.xxx.xxx)
Default IP address: 192.168.254.254
(no padding)
Default gateway IP address: 0.0.0.0
Default DNS server IP address: 0.0.0.0
X1&
= Subnet mask
Default: 255.255.0.0 (no padding)
X1*
= Hardware MAC address
(00-05-A6-NN-NN-NN)
X1(
Time in 10s of milliseconds to wait for
characters coming into a serial port before
terminating (min=0, max=32767 and
default=10=100 ms). The response is
returned with leading zeros.
X2)
Time in 10s of milliseconds to wait
between characters coming into a
serial port before terminating (min=0,
max=32767 and default=2=20 ms). The
response is returned with leading zeros.
Commands using both
X1&
and
X2)
must have both values = 0 or both set
non-zero.
X2!
Parameter to set either Length of message
to receive or Delimiter value. L=#=byte
count (min=0, max=32767. default=0L=0
byte count).
D = decimal value for ASCII character.
(min=0, max=00255. Default=00000L).
Value is placed prior to parameter: 3 byte
length = 3L and ASCII 0A delimiter is 10D.
The parameter is case sensitive, must
use capital D or capital L. The response is
returned with leading zeros.
X2@
Priority status for receiving timeouts:
0=use Send data string command
parameters (if they exist).
1=use Configure receive timeout
command parameters instead (default=0).
X2#
= Verbose mode
0=clear/none (default for Telnet
connections
1=verbose mode (default for USB and
RS-232 host control)
2=tagged responses for queries
3=verbose mode and tagged responses
for queries
X2%
= RS-232 baud rate (9600 [default], 19200,
38400, 57600, 115200)
X2^
= RS-232 parity: single letter:
Odd, Even, None (default)
X2&
= RS-232 data bits: 7, 8 (default)
X2*
= RS-232 stop bits: 1 (default), 2
X3#
= Password: maximum length 12
characters. All alpha-numeric characters
permitted except /,\,|,"space", and "*".
X4)
= Encode profile
1=base
2=main
3=high
X4!
= Output mode
1=video and audio
2=video only
X4@
= bit rate control type
0=VBR
1=CVBR
2=CBR
X4#
=
Video bit rate (200 to 10000)
X4$
=
Audio bit rate (80, 96, 128, 192, 256,
320)
X4%
=
GOP length (1 to 30)
161SMP351 • Remote Communication and Control