FT-111, User Manual Rev. 2.0.0, June 2022 Page 128 of 137
ALL Status (always 32 bit integer)
PLC Output to FT-111 Input.
Bit Number
Low Dword of TxPDO 1(T_UL1) Description
B31
Place of decimal point
0
None
1
No decimal point
B30
0
None
1
Decimal point is X.X
B29
0
None
1
Decimal point is X.XX
B28
0
None
1
Decimal point is X.XXX
B27
0
None
1
Decimal point is X.XXXX
Not in use
B13
High resolution status
0
Passive
1
Active
B12
Centre of zero
0
Weight is out of zero range
1
Weight is in zero range
B11
Key lock status
0
Passive
1
Active
Not in use
B6
Unit indication
0
First Unit (power on unit)
1
Second Unit
B5
Power On Zero
0
Not power on zeroed
1
Zeroed with power on zero
B4
Not in use
B3
Indication
0
Gross mode
1
Net mode
B2
Motion Detection
0
Stable
1
Unstable
Not in use
Table 13.1 ALL Status table