FT-111, User Manual Rev. 2.0.0, June 2022 Page 133 of 137
R/
W
Detection
Range
(1) (2)
1
± 0,5d
2
± 1d
3
± 2d
4
± 3d
5
± 4d
6
Disable
01000110
70
R/
W
Stability Time
(1) (2)
Refer to par. [517] page 62
01000111
71
R/
W
Unit
(1) (2)
0
g
1
kg
2
t
3
lb
4
oz
5
No
01001000
72
R/
W
Range
(1) (2)
0
Single range
1
2 x Multi Range
2
3 x Multi Range
3
2 x Multi Interval
4
3 x Multi Interval
01001001
73
R/
W
Capacity-1
(1) (2)
Refer to par. 523 on page 63
01001010
74
R/
W
Decimal
point-1
(1) (2)
0
XXXXOO
1
XXXXXO
2
XXXXXX
3
XXXXX.X
4
XXXX.XX
5
XXX.XXX
01001011
75
R/
W
Increment-1
(1) (2)
0
X1
1
X2
2
X5
01001100
76
R/
W
Capacity-2
(1) (2)
01001101
77
R/
W
Decimal point-2
(1) (2)
01001110
78
R/
W
Increment-2
(1) (2)
01001111
79
R/
W
Capacity-3
(1) (2)
01010000
80
R/
W
Decimal point-3
(1) (2)
01010001
81
R/
W
Increment-3
(1) (2)
01010010
82
R/
W
Limit of
Indication
(1) (2)
0
Over indication after Max
1
1 division more than Max
2
9 division more than Max
3
2% more than Max
4
5% more than Max
Table 13.3 - Expanded Command List
(1) Write this command after writing values to Low Dword of RxPDO then apply this command with New
CMD.
(2) To access the related value, read Low Dword of TxPDO.