FT-111, User Manual Rev. 2.0.0, June 2022 Page 60 of 137
DIGITAL OUTPUTS (Appears if the option is installed)
Press key or key again to enter this menu.
Press key to go to beginning of the sub-block or press
key to go to the next main block.
NO
SAIN
SIND
SANE
SNET
SGRO
SPC1
SPC2
STAB
ZR I
ZR G
ERRO
FBUS
Disable
Absolute Indicated weight
Indicated weight
Absolute net weight
Net weight
Gross weight
Control mode 1
Control mode 2
Weighing is stable
Zero range of indicated weight
Zero range of gross weight
Error
Controlled by Fieldbus or BSI command
For settings refer to Output 1
For settings refer to Output 1
For settings refer to Output 1
For settings refer to Output 1
Zero range in XX.X division. Default is 1.0 d.
For example: if the scale division is 0.5 kg and this
parameter entry is 1.0 division.
The output is activated if the indication is lower than
0.5 kg.
Immediately change even scale is not stable.
Change if the scale is stable.