Using CentreWare Internet Services
53
Environment Settings
2
z
Primary Server IP Address & Port
You can set the primary WINS server address.
z
Secondary Server IP Address & Port
You can set the secondary WINS server address.
îš„ Apply button
You can apply changes by pressing this button.
Note • Reboot the machine to enable new settings.
LPD (Connectivity > Protocols)
You can set the LPD port.
îš„ General
z
LPD Port Status
You can check [Enabled] to use LPD. (Default: On)
z
Physical Connection
[Ethernet] is displayed.
z
Port Number
You can set the LPD port No. (a value between 1 and 65535). You must set a unique
number for each port. (Default: 515)
z
Connection Time-Out
You can set the timeout period that the machine waits before terminating the connection
when incoming data stops (between 2 and 3600 seconds). (Default: 60)
z
Maximum Connections per Port
The maximum number of connections is displayed.
îš„ Apply button
You can apply changes by pressing this button.
Note • Reboot the machine to enable new settings.
Port9100 (Connectivity > Protocols)
You can set Port9100.
îš„ General
z
Port9100 Port Status
You can check [Enabled] to use Port9100. (Default: On)
z
Physical Connection
[Ethernet] is displayed.
îš„ Port Information
z
TCP Port Number
You can set the Port9100 port No. (a value between 1 and 65535).
You must set a unique number for each port. (Default: 9100)
z
Maximum Connections per Port
The maximum number of connections is displayed.