528 U41117-J-Z125-7-76
Message lines Explanation of console messages
Response
If the VLP and SVLP are running correctly automatic switchover should be initiated
manually.
SXVW026 VLPWATCH: ALERT: VW(#026) switch VLP/SVLP to SVLP/VLP timed out - reboot!
Meaning
The switchover from the VLP to the SVLP or from the SVLP to the VLP cannot be
completed. The ISP is rebooted.
Response
A reboot is the automatic response.
SXVW027 VLPWATCH: NOTICE: VW(#027) AutoVLP-Failover: other ISP is currently switching
- wait maximum %d minutes
Meaning
The automatic switchover is currently running on the other ISP of the type “VLP”.
SXVW028 VLPWATCH: ALERT: VW(#028) AutoVLP-Failover: both communication sectors are
empty in bootphase!
SXVW028 VLPWATCH: ALERT: VW(#028) AutoVLP-Failover: connection to LAN and start of
CentricStor prevented!
SXVW028 VLPWATCH: ALERT: VW(#028) AutoVLP-Failover: please reconfigure this function!
Meaning
In the boot phase it is ascertained that the AutoVLP failover function is to be activated, but
the communication sectors are empty; the function is configured incorrectly. The ISP is
placed Disconnect mode. No connection to: LAN, caches and DB.
Response
The function must be deconfigured manually and disconnect mode must be canceled (see
Service Manual), and the ISP must then be rebooted.
SXVW029 VLPWATCH: NOTICE: VW(#029) AutoVLP-Failover: wait until other ISP is switching
- wait maximum %d minutes
Meaning
Max. %d minutes are waited until the other ISP (SVLP) has taken over the VLP functionality.
SXVW030 VLPWATCH: ALERT: VW(#030) AutoVLP-failover: other ISP does not start switch -
continue
Meaning
The VLP is rebooted by “swap master” and waits until the SVLP switches to become the
VLP. If this does not happen within 10 minutes the boot procedure is continued and,
depending on the current situation, the old VLP switches to become the SVLP or retains its
VLP status.
Response
None or repeat “swap master”.