EasyManuals Logo

Fujitsu Siemens Computers pmn User Manual

Fujitsu Siemens Computers pmn
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #530 background imageLoading...
Page #530 background image
530 U41117-J-Z125-7-76
Message lines Explanation of console messages
SXVW038 VLPWATCH: NOTICE: VW(#038) AutoVLP-Failover: VLP is alive: wait max. 180 seconds
before a failover, if VLP is not alive
Meaning
The VLP has already provided a sign of life in the extended monitoring time of 7 or 5 minutes
in the boot or start phase; the monitoring time is now reduced to 3 minutes (default).
This message can only occur on the current SVLP.
SXVW039 VLPWATCH: NOTICE: VW(#039) AutoVLP-Failover: reboot to switch!
Meaning
A manual VLP switchover was initiated via “swap master”. The VLP is therefore rebooted.
This message can only occur on the current VLP.
SXVW040 VLPWATCH: NOTICE: VW(#040) AutoVLP-Failover: open error of /etc/vtls/
vlpwatch_started (errno=%d); terminated
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW041 VLPWATCH: NOTICE: VW(#041) AutoVLP-Failover: lock error of /etc/vtls/
vlpwatch_started (errno=%d), terminated
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW042 VLPWATCH: NOTICE: VW(#042) AutoVLP-Failover: open error of /etc/vtls/
vlpwatch_daemon_started (errno=%d); terminated!
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW043 VLPWATCH: NOTICE: VW(#043) AutoVLP-Failover: lock error of /etc/vtls/
vlpwatch_daemon_started (errno=%d), terminated!
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW044 VLPWATCH: NOTICE: VW(#044) AutoVLP-Failover: VLP is alive!
Meaning
The SVLP logs that the VLP is available.
SXVW045 VLPWATCH: NOTICE: VW(#045) AutoVLP-failover: VLP is not alive (%d Seconds)!
Meaning
The SVLP has not been able to reach the VLP for %d seconds!