Status Description
blue on The server has been highlighted using ServerView
Operations Manager, the iRMC S5 web interface or
the ID button on the front panel for easy identification.
flashing blue The server has been highlighted for easy
identification using the iRMC S5 (A
VR) with disabled
local VGA output.
CSS indicator (2)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
For HDDs, see also "HDD prefailure detection" on
page 420.
flashing orange
CSS component failure detected.
Global Error indicator (3)
See also "iRMC-related status signals" on page 420.
Status Description
off No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange
Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
– Defective sensor
–
CPU error
– Error detected by server management software
Appendix A