Note on CSS and Global Error indicators on the I/O panel:
If CSS and Global Error indicators are located in the same place on the
I/O panel of the server, also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
For more information on detected errors, see the System Event Log or
use the ServerView Operations Manager or iRMC S5 web interface.
iRMC-related status signals
ID indicator Global error
indicator
Description
flashing blue
off A remote connection has been
established. Local VGA output has been
disabled during the remote session.
flashing blue flashing orange An emergency flash of the iRMC firmware
is in progress.
For more information about the iRMC flash procedure, see "Basic
software procedures" in the "FUJITSU Server PRIMERGY RX2530 M6
Upgrade and Maintenance Manual".
HDD prefailure detection
Depending on your hardware configuration HDD prefailure detection will be
supported.
The requirements are:
iRMC S5 Firmware 1.2 or later
supported OOB RAID system