CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID
Management" user guide.
If applicable,"Removing the front cover with lock" on page 45
.
Removing a 2.5-inch HDD/SSD module
Pinch the green locking clips and open the locking lever (see Figure 59).
Pull the HDD/SSD module out a few centimeters.
Wait about 30 seconds.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
This period is necessary for the RAID controller to recognize that an
SSD module has been removed.
Pull the HDD/SSD module completely out of its bay
.
Installing a 2.5-inch dummy module
CAUTION
If the removed HDD/SSD module is not replaced immediately,
always replace a dummy module into the unused HDD/SSD bay to
comply with applicable EMC regulations and satisfy cooling
requirements.
Hard disk drive (HDD) / solid state disk (SSD)