"Resuming BitLocker functionality" on page 104
.
For CPU1 and CPU2 on the bottom system board:
▶
"Installing the air duct 2 (bottom system board)" on page 72.
▶
"Installing the top system board carrier" on page 76.
▶
"Installing the air duct 1 (top system board)" on page 71.
▶
"Installing a riser module" on page 63.
▶
"Reassembling" on page 53.
▶
"Connecting the power cord" on page 59.
▶
"Switching on the server" on page 60.
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the
[F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the Exit menu.
●
Select Commit settings and Exit.
●
Verify that the Global Error indicator stops flashing.
▶
If applicable, "Installing the front cover with lock" on page
61.
▶
"Resuming BitLocker functionality" on page
104.
Liquid cooling (LC)
RX4770 M6 Upgrade and Maintenance Manual 297