Graupner HoTT General Engine Module
No. 33610
General sensor for Graupner HoTT receivers and models with gas
engine or electric motor
2x temperature and voltage measurements with warning thresh-
olds for min. and max. voltage and min. and max. temperature
Single cell measurement with warning thresholds for min. volt-
age
Voltage, current and capacity measurement with warning thresh-
olds for min. and max. voltage, max. capacity and max. current
Programmable current limiting
Current limiting with shunt resistors 2 x 1 mOhm parallel = 0.5
mOhm
Rotational speed measurement and warning thresholds for min.
and max. rotational speed
Fuel measurement with warning thresholds in 25 % increments
(after software update).
Settable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
stant
Settable repeated warning time: constant, 1, 2, 3, 4, 5 min., once
2x temperature selectively 0 to 120°C or 200°C and voltage
measurement up to 80 V DC
1x rotational speed measurement up to 100,000 rpm with a two-
blade propeller
1x speed controller/servo input, 1x rotational speed regulation
input, 1x speed controller/servo output for rotational speed reg-
ulation
1x current and voltage and capacity measurement up to 40 A
(short-term 1 sec 60 A) and up to 30 V
1x single cell monitoring for 2 - 6S lithium batteries (LiPo, lithium
ion, LiFe), see www.graupnerusa.com for the related items
Graupner HoTT General Air Module
No. 33611
General sensor for Graupner HoTT receivers and models with gas
engine or electric motor
Vario with altitude signals and ascent and descent signals, and
additional warning thresholds for min. altitude, max. altitude,
rate of ascent and descent in two stages
Altitude display (-500 to +3000 m) and storage of the min. and
max. altitude.
2x temperature and voltage measurements with warning thresh-
olds for min. and max. voltage and min. and max. temperature
Single cell measurement with warning thresholds for min. volt-
age
Voltage, current and capacity measurement with warning thresh-
olds for min. and max. voltage, max. capacity and max. current
Rotational speed measurement with rotational speed regulation
(programmable) and warning thresholds for min. and max. rota-
tional speed
Fuel measurement with warning thresholds in 25% increments
Settable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
stant
Settable repeated warning time: constant, 1, 2, 3, 4, 5 min., once
2x temperature selectively 0 to 120°C or 200°C and voltage
measurement up to 80 V DC
1x rotational speed measurement up to 100,000 rpm with a two-
blade propeller
1x speed controller/servo input, 1x rotational speed regulation
input, 1x speed controller/servo output for rotational speed reg-
ulation
1x current and voltage and capacity measurement up to 40 A
(short-term 1 sec 60 A) and up to 30 V
etc., see www.graupnerusa.com for the related items
Graupner HoTT Electric Air Module
No. 33620
General sensor for Graupner HoTT receivers and models with elec-
tric motor
Vario with altitude signals and ascent and descent signals, and
additional warning thresholds for min. altitude, max. altitude,
rate of ascent and descent in two stages
Altitude display (-500 to +3000 m) and storage of the min. and
max. altitude.
2x temperature and voltage measurements with warning thresh-
olds for min. and max. voltage and min. and max. temperature
Single cell measurement 2 - 14 s with warning thresholds for
min. voltage
Voltage, current and capacity measurement with warning thresh-
olds for min. and max. voltage, max. capacity and max. current
Settable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
stant
Settable repeated warning time: constant, 1, 2, 3, 4, 5 min., once
2x temperature selectively 0 to 120°C or 200°C and voltage
measurement up to 80 V DC
1x speed controller input, 1x speed controller output for single
cell undervoltage correction
1x current and voltage and capacity measurement up to 150 A
(short -term 1 sec 320 A) and up to 60 V
1x single cell monitoring for 2 - 14S lithium batteries (LiPo, lith-
ium ion, LiFe)
1x Telemetry connection for receiver