EasyManua.ls Logo

GRAUPNER mz-24 PRO - Page 75

GRAUPNER mz-24 PRO
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Press the INC or DEC button at the right edge of
the display or the arrow keys ( pq ) to the left of the
display screen to increase/decrease time (between
00:00 to maximum 59:59), as shown below:
BACK
MODE
START SW
RESET SW
TIMER1
59
NULL
NULL
T.RES
LAP SW
000
LAP List
NULL
UP
ALARM
59
00
DEC
RES
INC
NEXT
>>
:
:
STOP SW
NULL
LAP ALARM
OFF
Timer
Press the RES button to reset the changed value
back to the default.
Forward-counting timer (UP)
Forward-counting timers start at 000:00.
Backward-counting timer (DOWN)
Backward-counting timers start at -000:00. Press the
button in the MODE line to change to this option:
BACK
MODE
START SW
RESET SW
TIMER1
59
NULL
NULL
T.RES
LAP SW
000
LAP List
NULL
UP
ALARM
59
00
DEC
RES
INC
NEXT
>>
:
:
STOP SW
NULL
LAP ALARM
OFF
Timer
Press
BACK
MODE
START SW
RESET SW
TIMER1
59
NULL
NULL
T.RES
LAP SW
000
LAP List
NULL
DOWN
ALARM
59
00
DEC
RES
INC
NEXT
>>
:
:
STOP SW
NULL
LAP ALARM
OFF
Timer
Notice
If a timer is started, then stopped and switched
from forward to backward counting (or vice ver-
sa), only the remaining time on the timer is updat-
ed; the time is not reset.
Start/Stop Timer1 and Timer2
Timer 1
This timer can only be started through a switch as-
signed in the START SW line. In the example be-
low, the S8 switch is assigned to start the timer
and the S2 switch has been assigned to stop the
timer.
BACK
MODE
START SW
RESET SW
TIMER1
00
NULL
SW 8
T.RES
LAP SW
000
LAP List
NULL
UP
ALARM
00
00
DEC
RES
INC
SW
>>
:
:
STOP SW
SW 2
LAP ALARM
OFF
Timer
Notice
Stopping Timer 1 also stops the data log re-
cording to the SD memory card.
Timer 2
This timer can be started and stopped by tapping
on the minutes or seconds field or alternatively
through a switch assigned in the START SW line:
BACK
MODE
RESET SW
TIMER2
00
NULL
T.RES
LAP SW
000
LAP LIST
NULL
UP
ALARM
00
00
DEC
RES
INC
NEXT
>>
:
:
START SW
SW 6
LAP ALARM
OFF
Timer
Press
Press
Resetting Started Timers
1. Both Timer 1 and Timer 2 can be reset to the de-
fault value at any time by tapping on the related
timer field in the basic display
000
000
000
000
mz
000%
000%
000
000
BATT TIME 00: 01: 23
MODELLNAME 1
M - 1
PHASE 1
000:00.0
000:00.0
4.2V
0:01:23
Press
Press
2. Both Timer 1 and Timer 2 can be reset to the de-
fault value at any time by pressing the T.RES but-
ton in the Timer1 and Timer2 displays:
BACK
MODE
RESET SW
TIMER2
00
NULL
T.RES
LAP SW
012
LAP LIST
NULL
UP
ALARM
00
34
DEC
RES
INC
NEXT
>>
:
:
START SW
SW 6
LAP ALARM OFF
Timer
Press
75
Base menu - Timers

Table of Contents

Other manuals for GRAUPNER mz-24 PRO

Related product manuals