Internal Pulse Mode Gate
Programming Codes
SCPI: PULM:INTernal:WIDTh <num>[time suffix]lMAXimumJMINimum
Analyzer: NONE
See Also
0,
1
MOD a so see “Pulse” and “Modulation”.
Internal
Pulse
Mode
Auto
Function Group
(MOD_)
Menu Map
4
Description
This softkey (Option 002 only) is the default mode of generating
internal pulses. It is not synchronized to any trigger signal. An
asterisk next to the key label indicated that this mode is selected.
Programming Codes
SCPI: PULM:INTernal:TRIGger:SOURce
INTernal
Analyzer: NONE
See Also
0,
1
MOD
a so see “Pulse” and “Modulation”.
Internal
Pulse
Mode
Gate
Function Group
(MOD_)
Menu Map
4
Description
This
softkey
(Option 002 only) logically “ANDs” the internal pulse
generator with a gating signal supplied from an external source.
Programming Codes
SCPI:
PULM:INTernal:GATE
ONlOFFlllO
PULM:INTernal:TRIGger:SOURce
INTernal
Analyzer: NONE
See Also
m),
also see “Pulse” and “Modulation”.
Operating and Programming Reference
I-1 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8360 B Series and is the answer not in the manual?

HP 8360 B Series Specifications

General IconGeneral
BrandHP
Model8360 B Series
CategoryPortable Generator
LanguageEnglish

Related product manuals