EasyManuals Logo

Hypertherm Powermax 125 Service Manual

Hypertherm Powermax 125
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
162 Powermax125 Service Manual 808070
8 Troubleshooting and System Tests
Test 9 Electronic regulator
Symptom: Air flows continuously through the torch.
1. Turn OFF the machine and disconnect the power.
2. Disconnect the electronic regulator control cable (J6) from the power board.
If air continues to flow, replace the electronic regulator.
If the air stops flowing, verify the DSP board by replacing it with a known good one. If the DSP board is not the
problem, replace the power board.
Figure 30
1
2
3
4
5
1 Electronic regulator (J6)
2 Pressure switch/auxiliary contactor (J5)
3 Pressure sensor (J3)
4 Inverter temperature sensor (J2)
5 Fan (J1)

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand

Related product manuals