6 Machine Torch Setup
105 A shielded cutting – aluminum
Air flow rate slpm/scfh
Hot 283 / 600
Cold 345 / 730
Metric
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds mm/min volts mm/min volts
6
4.6
9.2 200
0.5 6340 158 6390 154
8 0.6 4330 162 4690 154
10 0.8 2660 164 3250 155
12 0.7 2020 167 2590 159
16
11.5 250
1.0 1350 169 1550 157
20 1.3 970 172 1020 161
25
Edge Start
1.0
660 176 800 167
30 460 180 580 174
32 1.2 390 182 490 176
English
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm volts ipm volts
1/4
0.18
0.36 200
0.5 236 159 240 154
3/8
0.75
110 164 134 154
1/2 75 167 95 159
5/8
0.45 250
1.0
54 169 62 157
3/4 40 171 42 160
7/8 2.0 34 173 37 164
1
Edge Start
1.0 25 176 31 167
1-1/4 1.2 16 182 20 176

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand