32 Powermax125 Service Manual 808070
2 Power Supply Setup
Power connection for the Powermax125
Powermax125 3-phase systems are available in the following fixed-voltage configurations:
480 V CSA
600 V CSA
400 V CE
380 V CCC
To maintain CE certification, install power cord kit 228886.
The Hypertherm rated output is 30 125 A, 175 VDC.
Table 4 480 V CSA
Table5 600V CSA
Table6 400V CE
Input voltage (V) 480
Input current (A) at rated output (21.9 kW) 31
Input current (A) at arc stretch 50
Fuse, slow-blow (A) 50
Voltage tolerance +20% / -15%
Input voltage (V) 600
Input current (A) at rated output (21.9 kW) 24
Input current (A) at arc stretch 38
Fuse, slow-blow (A) 40
Voltage tolerance +10% / -15%
Input voltage (V) 400
Input current (A) at rated output (21.9 kW) 36
Input current (A) at arc stretch 55
Fuse, slow-blow (A) 60
Voltage tolerance +20% / -15%

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand