Powermax125 Service Manual 808070 37
2 Power Supply Setup
Connect the gas supply
Connect the gas supply to the power supply using an inert-gas hose with a 9.5 mm (3/8 inch) internal diameter and a
1/4 NPT quick-disconnect coupler (CSA units) or a 1/4 NPT x G-1/4 BSPP (CE/CCC units) quick-disconnect coupler.
WARNING!
Do not allow the gas supply pressure to exceed 9.3 bar (135 psi). The filter bowl may explode if this
pressure is exceeded.
The recommended inlet pressure while gas is
flowing is 5.9–9.3bar (85–135psi).