Powermax125 Service Manual 808070 165
Section 9
Power Supply Component Replacement
WARNING!
ELECTRIC SHOCK CAN KILL
Turn OFF the power and remove the input power plug from its receptacle before removing
the cover from the power supply. If the power supply is connected directly to a line
disconnect box, switch the line disconnect to OFF (O). In the U.S., use a “lock-out /
tag-out” procedure until the service or maintenance work is complete. In other countries,
follow appropriate national or local safety procedures.
Do not touch live electrical parts! If power is required for servicing, use extreme caution
when working near live electrical circuits. Dangerous voltages exist inside the power
supply that can cause serious injury or death.
Do not attempt to repair the power board or control board. Do not cut away or remove any
protective conformal coating from either board. To do so will risk a short circuit between
the AC input circuit and the output circuit and may result in serious injury or death.
See the Safety and Compliance Manual (80669C) included with your system for more
safety precautions.
CAUTION!
Static electricity can damage circuit boards. Use proper precautions when handling
printed circuit (PC) boards.
Store PC boards in anti-static containers.
Wear a grounded wrist strap when handling PC boards.

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand

Related product manuals